Installation Instructions
Product Description
Hardware
The sturdy and durable TV40 infrared thermal imager, paired with reliable and high-quality 320x240 or 640x480 resolution infrared detectors, allows you to view visualized temperature data during the manufacturing process anytime, anywhere.
Detailed Photos
IP67 (NEMA 4) rated protective enclosure ensures long-term use in harsh environments (can also be paired with air blowing and other accessories)
Product Parameters
temperature range
Spectral response
Infrared detector resolution -10 ° C to 1200 ° C (14 ° F to 2192 ° F)
8 to 14 µ m
Uncooled focal plane array (microcalorimeter)
TV43, infrared
TV46, infrared
TV43/TV46, Visible light frame rate 320 x 240 pixels (76800 pixels), 12 µ m spacing
640 x 480 pixels (307200 pixels), 12 µ m spacing
640 x 480 pixels
TV43, infrared
TV46, infrared
TV43/TV46, Visible photothermal time constant
Accuracy1
Minimum detectable temperature difference of 9 Hz or 60 Hz (frames per second)
9 Hz or 60 Hz (frames per second)
15 Hz (frames per second)
12 ms(90%)
± 2 ° C or ± 2% reading (whichever is greater)
NETD
Radiometric correction of 50 mK, measurement temperature of 0.10 to 1.00 at 30 ° C (86 ° F)
1. Blinking yellow - Start
2. Pure Yellow - Loading Operating System
3. Pure green - no errors, obtain IP address, and connect Ethernet cable
4. Flashing red - Multiple errors (unable to communicate with the engine)
5. Blinking Green - Flash Memory is Updating
6. Pure Blue - Shutter Closed
7. Pure red - exceeding ambient temperature
Please note that the thermal imager displays these modes in priority order, with higher numbered events masking lower numbered events. For example, the thermal imager is connected to Ethernet (pure green), but there is an overheating situation. under these circumstances, The LED displays pure red until the overheating condition is eliminated, and then the LED will display pure green.